Beijing Julongsanyou Technology Co., Ltd.

Product Detail

B-4500 Infant Incubator

B-4500 Infant Incubator
Detail

Product feature:

● ABS main body;

● LCD display screen, easily setting, clear and intuitive;

● Air temperature display and servo control;

● Skin temperature display and servo control, double skin temperature sensor;

● Humidity display and servo control;

● Display time and heater power;

● 24 hours Parametric trend diagram display;

● Audible & Visual Alarms: power failure, sensor failure, higher & lower temp, air & skin temperature override, fan failure, low water level, system failure;

● >37℃ Preset Mode: power failure reset memory,alarm silence, self-test function;

● Hood with single slope, big front door, 6 access ports, 4 tube grommet;

● 2 Storage cabinets, Protective guard rail, IV poles;

● RS-232 Output Connector (use for network system);

● Optional Pulse Oximeter monitor system;

● Optional oxygen concentration measure and control system;

● Optional ECG system;

● Optional baby weight scale system;

● Audio, video, and network interfaces are reserved for data and function extensions


Technical specification:

1 . Air temperature:

Air temperature display range: 0℃-60℃;

Air temperature control range: 20.0℃-37.0℃, 37.1℃-39.0℃

Air temperature accuracy: ≤±0.3℃;

Air temperature deviation alarm: ±3.0℃.

2 . Skin temperature:

Skin temperature display range: 0℃-60℃;

Skin temperature control range: 20.0℃-37.0℃, 37.1℃-38.0℃;

Skin temperature accuracy :≤±0.3℃;

Skin temperature deviation alarm: ±1.0℃.

3. Humidity

Humidity display range: 0%--99%RH;

Humidity control range: 30%--95%;

Humidity control accuracy: (10% - 90% at 20 - 40℃)±5%RH.

4. Oxygen concentration (Optional)

Oxygen concentration setting range: 21%-65%

Oxygen concentration display range: 18%-99%

Oxygen concentration display accuracy: 2%

Oxygen concentration control accuracy: 3%

5. Baby weight scale(Optional)

Weight range: 500g-10kg

Weight accuracy: ±10g

Display trend diagram of baby weight

6. Pulse Oximeter monitor (Optional)

SpO2: measure range 0-100%, display resolution 1%;

Pulse rate (PR): measure range 25-250bpm, display resolution 1bpm;

Perfusion index(PI): measure range 0-20%, display resolution 0.001%;

Variability index: measure range 0-100%, display resolution 1%.

7. ECG (Optional)

ECG measure range: 0.15mV-5.5mV

ECG measure accuracy: 2.36uV/LSB

Breath measure range: 15-120rpm

Heart rate measure range: 15-300bpm

Heart rate measure accuracy: ±1bpm

Body temperature measure range: 0-50℃

Body temperature measure accuracy: 0.1℃